Specify two opening diameters and a separate target land
For a tapered laser microvia, record the entry opening, the opening at the target surface, and the depth between named reference planes. Record the target-land diameter separately. Use the diameter and depth convention required by the applicable fabrication agreement when reporting aspect ratio; do not substitute whichever diameter produces the lower number.
The practical output is an annotated section and a dimension register tied to a layer pair, material construction and process stage. This article develops an illustrative section, compares two depth-to-diameter calculations and checks target-land coverage with tolerances. None of the example dimensions is a recommended production limit.
Define the measurement stage before choosing symbols
An as-formed opening, a cleaned opening before metallization and a plated or copper-filled structure are different inspection states. State which one a dimension describes. A filled microvia does not have an open finished bore that can be treated as the original laser aperture. Keep the CAD hole setting identifiable, but do not assume it directly specifies every physical diameter.
ESA’s Microvia process guidelines, Issue 1.0 dated November 18, 2020, recommends covering both top and bottom diameters in process qualification. It also distinguishes the internal target pad from the external pad because “capture pad” can be ambiguous. The document provides process recommendations and explicitly excludes design limits and acceptance criteria; it is not a general commercial capability table.
| Symbol | Definition for this example | Do not confuse it with |
|---|---|---|
| Dentry | Cavity opening diameter at the upper entry reference plane | The outside diameter of the external copper land |
| Dtarget | Cavity opening diameter where it reaches the target copper surface | The diameter of the target copper land itself |
| h | Distance from the entry plane to the top surface of the target copper | Total board thickness or an unspecified dielectric-only thickness |
| Ptarget | Target copper land diameter in the plan-view coverage calculation | A hole diameter to insert into an aspect-ratio formula |
If copper overhang or an irregular cavity creates a narrower opening elsewhere, record that restriction too. Two endpoint measurements cannot describe every wall profile. Use the laser-drilling review guide to connect the dimensional drawing to material and process questions.
Read a section with explicit reference planes
Here h starts at the upper entry plane, so it is not automatically the dielectric thickness alone. If a project uses another reference, redraw the dimension and rename the calculation. Record any intended target penetration separately rather than silently adding it to this example’s h.
Also identify drilling direction by physical layer names. In Altium Designer, the First Layer/Last Layer order controls microvia drill direction, as described in its via-definition documentation, updated October 5, 2026. A bottom-side via needs the appropriate entry-to-target mapping even if a register lists its layer numbers in ascending order.
Compare ratios without changing their meaning
For the illustrated cavity, h = 75 µm, Dentry = 100 µm and Dtarget = 60 µm. The calculations below are named geometric comparisons. They are not two alternative compliance tests, and neither establishes an IPC classification or approved process window.
| Quantity | Calculation | Meaning |
|---|---|---|
| Entry-based depth ratio | 75 / 100 = 0.75 | Uses the opening at the specified entry plane |
| Target-opening depth ratio | 75 / 60 = 1.25 | Uses the narrower opening at the target surface |
| Bottom-to-entry area ratio | (60 / 100)2 = 0.36 | Compares ideal circular opening areas only |
The second depth ratio is about 67% larger than the first. Reporting only “aspect ratio 0.75” discards the dimensional convention and the narrower bottom opening. The 0.36 area ratio is not a prediction of bond strength, plating quality, current capacity or lifetime. It simply illustrates why similar-looking entry openings can conceal different bottom geometry.
For acceptance, use the exact numerator, denominator, process stage and tolerances in the agreed specification and revision. The microvia aspect-ratio guide explains how to document that convention. Do not feed these as-formed dimensions into a tool labeled for another measurement stage without resolving the difference.
Check target-land coverage with the bottom opening
A separate plan-view screening calculation can estimate the narrowest remaining radial land margin. Assume a circular target land, a circular bottom opening and a resultant center offset e. When the opening remains inside the land, the geometric margin is:
m = (Ptarget − Dtarget) / 2 − e
Using Ptarget = 180 µm, Dtarget = 60 µm and an illustrative offset e = 20 µm gives m = 40 µm. This offset case is separate from the centered section shown above. If the land minimum is 170 µm, bottom-opening maximum is 70 µm and allowed resultant offset is 30 µm, the corresponding bound is (170 − 70) / 2 − 30 = 20 µm.
That 20 µm is a calculated geometric remainder, not a sufficient annular-ring requirement. Compare it with the agreed minimum and inspection method. If tolerances are specified independently in x and y, do not treat either component as the resultant offset; combine them according to the defined tolerance model. The calculation also does not account for target erosion, noncircular geometry or an inadequate copper interface.
Request evidence that matches the drawing
A useful measurement report identifies the process stage, reference planes, section orientation and sampling locations. Ask how the method captures the actual opening diameter rather than an off-center chord, and how irregular profiles are reported. Keep nominal values, permitted extremes and measured observations in separate columns.
ESA’s guideline recommends verification of the laser-formed geometry and target condition using methods such as microsectioning and microscopy, together with registration checks. Geometric inspection still has a limited purpose: IPC’s March 6, 2019 microvia reliability warning describes failures that escaped conventional acceptance checks. Use it as historical reliability context, not as the current acceptance standard for a new order.
- Identify the stackup revision, dielectric construction, entry layer, target layer and drilling direction.
- Specify each opening diameter, its tolerance, reference plane and measurement stage.
- State depth endpoints and any separate target-penetration requirement.
- Record external- and target-land dimensions plus the registration tolerance model.
- Request representative geometry and interface evidence for the proposed structure, including the agreed acceptance specification and revision.
Track these items with the HDI DFM release checklist. The three primary references were checked October 19, 2026. The section, arithmetic and tolerance example are original review aids; no production sample or reliability test was performed for this article.
Prepare a microvia geometry review
Include the annotated section, material and stackup revision, drill-pair files, dimensional tolerances, target-land sizes and registration assumptions. Add copper-fill or capping requirements, applicable acceptance documents, quantity and requested delivery date. Highlight any disagreement between CAD dimensions, fabrication notes and the measurement report.
Prepare your HDI manufacturing inquiry
For an initial discussion, contact WhatsApp +86 136 0042 7328.