Give each HDI via definition a traceable identity

A useful HDI padstack name helps a reviewer find the intended layer span, hole definition and land geometry. It does not prove that a placed via or exported drill file uses those settings. Pair a short review ID with a revision-controlled register, then check that register against the actual board and manufacturing outputs.

This article proposes a project naming convention and a worked reconciliation example. The convention is not an IPC naming standard, a CAD import format or a manufacturing capability specification. Use it as a review alias when your CAD system generates its own template names.

Separate the geometry template from the layer span

In Altium Designer, a Pad/Via template holds base geometry and related settings, including hole and mask information. Local templates can receive names derived from their configuration. By contrast, the Layer Stack Manager’s Via Types define layer-spanning requirements; diameter and hole size are defined elsewhere. For a microvia, the order of the First Layer and Last Layer settings also determines drill direction. These are different definitions to reconcile, even when the user interface presents them together.

The relevant primary references are Altium’s Pad/Via template documentation and via type and microvia output documentation, both marked updated October 5, 2026. Their terminology describes Altium’s implementation; other CAD systems may organize the same information differently.

Keep four records connected: the CAD geometry definition, the permitted layer span, the placed instances and the released fabrication requirements. A familiar template name is insufficient if one of those records belongs to a different board revision. The HDI design-rule guide explains how to tie rule scope to the approved construction.

Use short names with an explicit project legend

For an illustrative eight-copper-layer board, number physical copper layers from L01 at the top to L08 at the bottom. Map those numbers to the actual CAD layer names in the stackup revision. A possible review ID is MV_L01-L02_CF_G07_R02.

Example review-ID fields; these tokens are defined only for this project
TokenMeaningRequired companion record
MVMicrovia classCAD via type and the proposed fabrication operation
L01-L02Physical layer spanStackup revision and a separate entry-to-target direction
CFCopper-filled requirementFabrication note; capping and surface treatment remain separate fields
G07Geometry record 07Hole dimension meaning, units and land geometry by layer
R02Revision 02 of this review definitionFrozen register and matching library or board snapshot

The span token describes endpoints, not drill direction. For a bottom-side L07–L08 microvia, explicitly record entry L08 and target L07 in the register. Do not sort layer numbers and then assume the first number is the entry surface.

A label such as via100 leaves the unit and dimension meaning unresolved. microvia_small leaves both geometry and span unresolved. The proposed ID makes these omissions easier to find, but only if G07 and the stackup reference actually exist. Do not encode an unexplained number or use a “filled” flag to imply copper fill, resin fill, plating or capping interchangeably.

Make the register answer the manufacturing questions

Store a row for each released review ID and link it to the exact CAD object or combination of objects. The following worksheet defines the minimum information to resolve before release. It deliberately contains no default hole or land dimensions: those values need the selected stackup, package constraints and fabricator agreement.

Padstack and via-type register worksheet
Field groupRecord explicitlyReject the row when
Identity and scopeReview ID, CAD template identifier, via type, library/board revision and applicable board regionThe same ID points to incompatible definitions
Layer accessPhysical span, CAD layer mapping, entry and target, stackup revisionA span is inferred only from a filename or layer display order
Hole definitionCAD hole value, unit and its documented meaning; fabrication dimension references and tolerancesCAD diameter, laser entry diameter and finished-hole requirement are treated as the same value without agreement
Land geometryLand shape and size by applicable layer; clearance/antipad rules and their scopeA single land size hides an intentional layer-dependent difference
Fabrication treatmentPlated/non-plated status, fill material, cap requirement and applicable mask openings or tentingOne generic protection label substitutes for all these requirements
Release mappingOutput file or feature group, drill pair, units, origin and expected instance countThe released output cannot be matched back to the board revision

For a copper-filled microvia, an open finished bore is not the finished feature. Record which process-stage geometry a requested hole measurement describes. Keep the required fabrication treatment in the drawing or accepted structured-data fields as well as the register; a custom alias may never reach the fabricator’s CAM system.

Net connectivity, spacing rules and return-path decisions also need their own checks. Two vias with the same shape and span can serve different nets or electrical requirements. Conversely, two different spans may legitimately share one geometry template. Neither observation alone establishes that the proposed construction can be built.

Reconcile counts by span, not just by total

Consider a hypothetical board with two approved microvia groups. Both use geometry G07 and copper fill, but their spans differ. Count physical via instances in the same board revision and corresponding drill hits for these two groups only; exclude panel repeats and tooling from this comparison.

Illustrative mismatch: the total agrees while the layer-pair allocation does not
Review IDExpected instancesExported hitsExport minus expected
MV_L01-L02_CF_G07_R028084+4
MV_L02-L03_CF_G07_R024036−4
Total1201200

The arithmetic is 80 + 40 = 84 + 36 = 120, yet both groups fail reconciliation. The count result suggests a span assignment or output-mapping problem worth investigating; it does not prove that exactly four vias were moved. Compare instance locations and actual layer-pair content to locate the discrepancy. Even matching counts would not establish matching coordinates, dimensions or connectivity.

Altium’s documentation describes separate microvia drill output for each layer pair. Preserve that distinction when mapping the files to the register. More generally, exporter settings matter: the KiCad 10.0 PCB Editor manual documents separate plated and non-plated Excellon outputs by default, along with selectable drill units and origin. Its merge option should only be used when requested by the manufacturer. These export controls are evidence to record, not facts implied by a padstack name.

Use the drill-file requirements guide to extend the comparison to layer-pair naming, coordinate alignment and the release manifest.

Freeze and review the complete mapping

  1. Capture the baseline. Save the stackup revision, register and CAD/library snapshot together. Record the actual CAD application version and output settings.
  2. Resolve every placed definition. Match its span, geometry and fabrication treatment to a register row. Investigate local overrides or an old library link instead of assuming a renamed template updated every instance.
  3. Check the output. Open the released manufacturing data in a suitable viewer. Compare layer pairs, coordinates, counts, units and relevant dimensions with the baseline.
  4. Control changes. A changed span, fill requirement or geometry requires review of affected rows and instances. Revise the register and regenerate the release package; renaming alone is not validation.
  5. Close unresolved items. Record the fabricator’s answers against the exact revision. Use the HDI DFM release checklist to track evidence and remaining questions.

Source scope: the two Altium pages are current web documentation marked updated October 5, 2026; the KiCad reference is the English 10.0 manual branch. All were checked October 18, 2026. The ID convention, register and 120-instance example are original review aids, not results from a tested CAD project.

Prepare a padstack and drill-span review

For a useful inquiry, provide the stackup and board revision, CAD application/version, padstack or via-type register, relevant BGA ball map, drill-pair manifest and fabrication notes for fill and capping. Identify any unresolved diameter meaning, layer mapping or export mismatch, and include the target quantity and required delivery date.

Prepare your HDI project inquiry

For an initial discussion, contact WhatsApp +86 136 0042 7328.