Keep the test method attached to every Tg value
A PCB laminate can have more than one reported glass transition temperature because DSC, TMA and DMA observe different material responses and use different reporting endpoints. Compare values only after checking the method, endpoint, specimen and conditioning. A larger number measured by another method does not, by itself, establish a better material.
For an HDI material review, the useful output is a traceable comparison record. This article reads a real laminate data sheet, separates three measurement approaches and gives a worksheet for resolving an incomplete material requirement. It does not establish a fabrication capability or an acceptance limit for your board.
Read the two Tg statements in one real data sheet
The Isola FR408HR data sheet, revision E with an April 15, 2021 update date, states a DMA Tg of 230 °C on its first page. Its second-page typical-values table reports 190 °C by DSC and identifies IPC-TM-650 2.4.25C.
| Source location | Recorded value | Method detail available | What remains unresolved |
|---|---|---|---|
| Page 2, typical-values table | 190 °C, DSC | IPC-TM-650 2.4.25C | A typical value is not a measured result for the supplied lot. |
| Page 1, product description | 230 °C, DMA | DMA is named. | The statement does not identify the DMA endpoint, frequency or method revision. |
The published numbers differ by 230 − 190 = 40 °C. That arithmetic describes these two statements; it supplies no conversion formula. Keep both entries with their labels. Do not replace the DSC number with the DMA number in a requirement that specifies DSC, or assume that the DMA statement uses a particular loss peak.
Distinguish the measured response from the reporting endpoint
A method name tells you the kind of experiment. The endpoint tells you which feature of its result becomes the reported temperature. Both belong in the comparison.
| Approach | Response observed | Endpoint in the cited procedure | Review question |
|---|---|---|---|
| DSC: differential scanning calorimetry | Heat-flow response associated with a heat-capacity change | IPC-TM-650 2.4.25D uses the midpoint of the transition step; its software option also permits the steepest-deflection temperature, rather than onset. | Which allowed analysis choice and scan history were reported? |
| TMA: thermomechanical analysis | Dimensional change with temperature | IPC-TM-650 2.4.24C determines Tg from the intersection of extrapolated regions before and after the z-axis transition. | Does the report identify the specimen and the lines used? |
| DMA: dynamic mechanical analysis | Mechanical response during oscillating deformation | IPC-TM-650 2.4.24.4 uses a storage-modulus tangent intersection; it also allows separately reported loss-modulus or tan-delta peak temperatures. | Is the number an onset-style intersection or an alternative peak? |
The DSC reference is IPC-TM-650 2.4.25, revision D, November 2017, especially section 5.3.1. This is a separately consulted explanation of a defined DSC procedure. The FR408HR table cites revision C; reading revision D does not change that attribution or prove that D was used for the product value.
The TMA comparison follows IPC-TM-650 2.4.24, revision C, December 1994. Its section 6.2 cautions that DSC and TMA results can differ. For the separate question of accumulated thickness change over a temperature interval, use the CTE and z-axis expansion guide.
The November 1998 IPC-TM-650 2.4.24.4 DMA method has no revision letter printed in its header. Sections 5.4.1 and 5.4.3 distinguish the intersection and peak results. This procedure specifies 1 Hz and 2 °C/min; those settings cannot be assigned to an otherwise unspecified supplier result. Mechanical tan delta here must also be kept separate from the dielectric loss tangent used in signal-loss calculations.
These references describe their stated versions and scopes. The applicable purchase specification must identify the required method and revision. No universal temperature offset or fixed ordering of the three methods is established by this comparison.
Resolve an incomplete material requirement before scoring it
Consider a hypothetical drawing that says only “Tg ≥ 180 °C.” A reviewer receives a data sheet listing 190 °C DSC and another statement listing 230 °C DMA. Neither number resolves what the drawing intended to require. Selecting whichever looks higher would hide the missing test definition.
- Clarify the requirement. Obtain the required method, revision, reporting endpoint, specimen preparation and evidence needed for acceptance.
- Match the evidence type. Separate a supplier’s typical product value from a guaranteed minimum and from a test result for a specific material lot.
- Record the decision. If the clarified requirement is DSC, the DMA statement cannot independently demonstrate compliance. A typical DSC value above the threshold can support screening, but it still does not prove lot acceptance.
The example’s 180 °C threshold is invented solely to illustrate document review. It is not a recommended HDI material specification. A release decision should retain the clarified requirement and its supporting evidence together, so a later material substitution can be reviewed against the same basis.
Build a comparison record that survives a supplier change
Use one record per reported result. Leave missing fields explicitly unresolved instead of borrowing details from a different product or method.
- Material identity: manufacturer, grade, construction, copper option and whether the specimen represents laminate, cured prepreg or a completed construction.
- Document identity: source page, revision, issue date and the original method reference.
- Test definition: measurement approach, endpoint, scan rate and, for DMA, frequency and loading arrangement.
- Specimen history: cladding condition, preparation, conditioning, cure history and the scan used for reporting.
- Evidence status: typical value, specified minimum or measured result, with the associated acceptance requirement.
The cited DMA method distinguishes a standalone HDI dielectric from a built-up composite, whose response may contain multiple contributions. This is another reason to identify what was tested. A material-family label alone is insufficient to describe the specimen.
Use the HDI material selection tool to organize initial electrical, thermal and construction needs. It is a screening aid, not a Tg measurement or acceptance calculator. The high-Tg FR-4 guide explains the broader limits of using Tg alone, while the HDI materials directory connects the remaining selection questions.
The four primary documents were rechecked October 30, 2026. The comparison tables, arithmetic and hypothetical review workflow are original explanatory aids. No thermal test or production-lot assessment was performed for this article.
Prepare an HDI material review
Include the exact material and construction, copper option, dielectric and board thicknesses, and electrical and thermal requirements. Attach the relevant data-sheet revision and state the required Tg method, endpoint and acceptance evidence. If two documents disagree, identify the precise rows being compared. Add the stackup, quantity and requested delivery date so the inquiry can address the complete project.
Request an HDI material review
For an initial discussion, contact WhatsApp +86 136 0042 7328.